Schedules have been standardized on minimum thickness rather than nominal thickness of sheet metal a major change. This edition improves upon the second edition with expanded pressure class tables. Codes and standards that are standard at the university. This reference contains tables and details for constructing duct work from. Use the minimum length of flexible duct needed to make the connections. Smacna hvac duct constructions standards questions part 1 1.
Smacna hvac duct construction standards metal and flexible, third edition 2005. Hvac duct construction standards metal and flexible rs34. Guidelines for inspection of commercial hvac duct systems for compliance with smacnas hvac duct construction standards, metal and flexible, and smacnas fibrous glass duct construction standards. The third edition of the hvac duct construction standards metal and flexible is intended primarily for commercial and institutional duct construction. Fibrous glass duct liner standard hvac duct construction. This means, when fabricating and installing the sheet metal duct work that serves the hvac portion of the building construction, care must be exercised that the air. Ansismacna 0062006 hvac duct construction standards.
Seismic restraint manual guidelines for mechanical oshpd. Available in pdf or cd only 1st edition, 2009, 146 pages. Comply with smacnas hvac duct construction standards metal and flexible, chapter 3, round, oval, and flexible duct, based on indicated staticpressure class unless otherwise indicated. Since all flexible ducts are not alike, use the flexible duct manufacturers air friction loss data to size the ducts whenever possible. Ducting may be categorized according to the materials of construction and are either metallic or nonmetallic ducts. Offers guidance on hvac equipment early startup and duct cleanliness for new construction. A comprehensive duct layout indicating sizes, design airflows, pressure class. This third edition of the smacna commercial metal and flexible duct construction standards is another in a long line dating from the 1950s. This american national standard ansismacna 006 contains tables and deta. Hvac duct construction standards metal and flexible smacna.
Smacna hvac duct constructions standards questions. Product detail sheet metal and air conditioning contractors. Hvac duct construction standards metal and flexible, 3rd. The third edition of the hvac duct construction standards u metal and flexible is intended primarily for commercial and institutional duct construction. Hvac duct construction standards march, 2010 presented by. Hvac ducting principles and fundamentals 2012 instructor. Smacna duct construction free download as pdf file. Smacna is the sheet metal and air conditioning contractors national association. This special edition of the smacna seismic restraint manual oshpd edition has been developed to meet the specific requirements of the california office of statewide health planning and development oshpd for hospital and health care facilities construction.
Hvac duct construction standards metal and flexible snips. Overall hvac duct system design issues are beyond the scope of this standard. Sheet metal and air conditioning contractors national. Naima fibrous glass duct construction standards smacna hvac duct construction standards, metal and flexible ul heating, cooling, ventilating and cooking equipment directory ul standard 181 factorymade air ducts and air connectors ul standard 181b closure systems for use with flexible air ducts and air connectors. Where fittings of configurations not shown in the hvac dcs are shown on the contract drawings, they shall be constructed as though they were therein. Smacna 19662005 hvac duct construction standards metal. When installing rectangular ducts using flexible liner, metal nosings shall be used on the upstream edges of. The following tests of rectangular duct sections and transverse joints were conducted in accordance with section vii of the smacna hvac duct construction standards, 2nd ed.
Hvac systems testing, adjusting and balancing, 3rd edition. This american national standard ansismacna 006 contains tables and details for constructing ductwork for. Smacna hvac duct construction standards metal and flexible. Hvac duct construction standards metal and flexible third edition iii foreword this third edition of the smacna commercial metal and flexible duct construction standards is another in a long line dating from the 1950s. Apr 24, 2020 the hvac duct construction standards is a smacna publication which deals with all aspects of metal and flexible duct construction. The standard contains tables and details for constructing ductwork for o to 10o wg positive and negative pressures. This edition improves upon the second edition with expanded pressure class tables, separate tables for tdctdf construction and. Howard, iii sheet metal and air conditioning contractors national association. Hvac duct construction standards metal and flexible, 3rd edition 2006 smacna. However, if satisfactory duct system performance is to be achieved, it is important for the system designer to calculate hvac loads on a roombyroom basis and to size ducts. Documents preceding 3rd edition hvac dcs hvac duct construction standards metal and flexible. Smacna hvac duct construction standards metal and flexible, 3rd ed.
Smacna sheet metal and air conditioning contractors. Smacnas hvac duct construction standards metal and flexible. Download smacna standards for duct construction, metal and flexible for hvac systems. Smacna 1981 pdf smacna 2005 pdf smacna duct construction smacna third edition 2005 smacna 2005 3rd edition smacna round duct smacna hvac duct construction smacna testing adjusting balancing smacna standard 3rd edition. Comply with ashrae fundamentals handbook and ashrae systems and equipment for design and fabrication of ductwork. Methods to identify and remediate lead, asbestos, or other materials that are classified as hazardous materials are not intended to be within the scope of this standard. A quick overview of the changes is provided in the front of this manual.
If no data is available, use the generic flexible duct friction loss chart in acca manual d. The standard contains tables and details for constructing ductwork for 12 to 10 wg positive and negative pressures. As an ansiaccredited standards developing organization, smacna standards and manuals address all facets of the sheet metal industry, from duct construction and installation to air pollution control, energy recovery and roofing. Smacnahvac duct construction standardsmetal and flexible, third edition 2005. Hvac duct construction standards metal and flexible s second. Air flow problems have plagued the hvac industry for years. This american national standard ansismacna 0062006 contains tables and details for constructing ductwork for.
Fibrous glass duct liner standard hereinafter referred to as naima fgdls, or of the sheet metal and air conditioning contractors national association hvac duct construction standards metal and flexible hereinafter referred to as smacna hvac dcs or the manufacturers recommendations. Hvac duct construction standards, metal and flexible. Hvac duct construction standards metal and flexible. Ansismacna 0062006 hvac duct construction standards eli p. The standard contains tables and details for constructing ductwork for.
Smacna standard ansismacna 006 hvac duct construction. Hvac duct systems inspection guide, 3rd edition 2004 smacna. The majority of ducts are constructed of metal and installed by tradesmen called sheet metal workers. Book by sheet metal and air conditioning contractors national association, 2005. Smacna duct construction standards download smacna standards for duct construction, metal and flexible for hvac systems. In fact, sheet metal use in hvac is greater than all other materials combined. Smacna duct construction standards metal and flexible. The hvac duct construction standards is a smacna publication which deals with all aspects of metal and flexible duct construction. Certified copies of these tests are available upon request. Existing metal ducts shall be permitted to be used where cooling coils are added to a heating system, provided the first 10 feet 3048 mm of the duct or plenum measured from the cooling coil discharge are constructed of metal of the gauge thickness in accordance with smacna hvac duct construction standards metal and flexible. Smacna sheet metal air conditioning contractors national association hvac duct. Vertical riser supports shall be installed at maximum spacing intervals of. Resin used shall be the hetron 197 for its fire retardant and corrosion resistant properties.
The brandnew 3rd edition comes complete with new and expanded tables from older editions. Hvac sound and vibration manual, 1st edition 2002 smacna. The hvac duct construction standards 3rd edition is the guide you need for commercial and institutional duct construction. Smacna 0062006 hvac duct construction standards metal and. Diffusion council adc publication, flexible duct performance and installation standards.
981 728 1172 1296 123 1017 82 771 1459 151 356 1167 965 1031 604 286 1242 1152 1381 125 1134 951 1065 720 896 738 298 1152 1286 793 679 253 1386 61 407